Products

Without test, measurement is not possible. Gain deeper confidence, see the real performance of your RF and Microwave signal.

TL6000 Large Dynamic Range OTDR

The TL6000 OTDR can used to test single-mode wavelengths of 1310nm, 1550nm, 1490nm, 1625nm and 1650nm, multi-mode wavelengths of 850nm and 1300nm as well as customized special wavelengths. It provides multiple optional modules, such as single wavelength, multi-wavelength and online test. With the maximum dynamic range of up to 50dB, the device can be used for remote multi-branch communication network test. It’s designed with a minimum event dead zone of 0.5m which makes the near connection easy to be supervised, and the lowest sampling resolution of 2.5cm which enables it to locate the event point accurately.

Product Details

Product Overview
The TL6000 OTDR can used to test single-mode wavelengths of 1310nm, 1550nm, 1490nm, 1625nm and 1650nm, multi-mode wavelengths of 850nm and 1300nm as well as customized special wavelengths. It provides multiple optional modules, such as single wavelength, multi-wavelength and online test. With the maximum dynamic range of up to 50dB, the device can be used for remote multi-branch communication network test. It’s designed with a minimum event dead zone of 0.5m which makes the near connection easy to be supervised, and the lowest sampling resolution of 2.5cm which enables it to locate the event point accurately. Additionally, the device is also designed with multiple convenient functional options, such as stable light source, optical power meter, visible red light source and fiber end face inspection tester.
TL6000 OTDR is designed with an operating temperature and a storage temperature of -10℃~50℃ and -40℃~70℃ respectively to meet both EMC requirements as well as vibration and shock test requirements, a MTBF(θ0) of 6000h or above to ensure a high reliability, and a 75W built-in Li battery to ensure an endurance for continuous measurement in the wild field.

Main Characteristics
1.A maximum dynamic range of 50dB, and 256k data sampling points
2.Online test of PON network
3.Integrated single-mode and multi-mode test
4.Automatic monitoring of optical communication signals
5.File formats of Bellcore GR196 and SR-4731 supported

 

 

Rapid automatic test
Due to the automatic test function of TL6000, it’s not necessary for the user to know more about its operation. Connect the optical fiber and press the [Test] button. Then, the device will set the optimum test conditions automatically, and finally output accurate test results, such as the test curve and the list of events.
Unique PON network test

As an ideal tester of ODN and FTTx, TL6000 is provided a unique built-in PON network test function, can penetrate an optical splitter of up to 1:128, and can be used to test each branch of the PON network accurately.

Automatic monitoring and alarm of incoming optical signals

When the OTDR is testing the optical fiber line, the optical communication signal in the optical fiber, if any, will lead to inaccurate test results and even unrecoverable damages to the detectors in the device. TL6000 can monitor the optical communication signal in the optical fiber under test automatically. As long as the optical fiber under test is connected to the optical interface of TL6000, the device can automatically sense and monitor whether there is optical communication signal in it. Once an optical signal is monitored, it will prompt an alarm in time, so as to provide the quickest and the most timely protection for the device.

Typical Applications

Specifications

Technical Specifications

Maximum

dynamic range

See the “Technical specifications for each standard module of TL6000 OTDR” for more information.
Ranging

accuracy

±(0.75 + sample interval + 0.0025% × range)(excluding the refractivity

placement error) (m)

Ranging

resolution

0.05, 0.1, 0.2, 0.5, 1, 2, 4, 8, 16 and 32m
Test range 0.4, 0.8, 1.6, 3.2, 6.4, 16, 32, 64, 128, 256 and 512km (single-mode);

0.4, 0.8, 1.6, 3.2, 6.4, 16 and 32km (850nm multi-mode)

Testing PW 3, 5, 10, 30, 80, 160, 320, 640, 1280, 5120, 10240 and 20480ns

3, 5, 10, 30, 80, 160, 320, 640 and 1280ns(850nm multi-mode)

Maximum number of

sampling points

 

256k

Linearity 0.03dB/dB
Loss resolution 0.001dB
Refractivity

setting range

1.00000 ~ 1.99999(step: 0.00001)
Range unit km, m, thousand feet, feet
Display 800×480, 7-inch TFT color LCD (a capacitive touch screen in the

standard configuration, and a resistive touch screen optional)

Optical output

interface

FC/UPC (standard configuration, with LC/UPC, SC/UPC and ST/UPC

optional)

Interface

language

Simplified Chinese, English, Russian and Korean available (contact the

office for other language support)

External

interfaces

USB, Micro-USB, 10M/100M Ethernet, earphone and Micro SD
 

Power supply

AC/DC adapter: AC100V~240V, 50/60Hz and 1.5A DC: 17V±3V(2A)

Internal Li battery: 11.1V, 6800mAh, battery operating time: 8h

Maximum power

consumption

10W
Dimensions 252mm(W)×180mm (H)×55mm (D)
Weight About 1.8kg
 

Environmental adaptability

Operating temperature:

-10℃~+50℃ (battery charging: 5℃~40℃)

Storage temperature: -40℃~+70℃ (battery: -20℃~60℃)

RH: 5% ~95%, no condensation

1.VFL (optional)
Operating wavelength: 650nm±20nm Output power: 2mW (typical) Operating mode: CW, 1Hz and 2Hz
2.Optical power meter (optional)
Wavelength range: 850nm~1650nm Power range: -60dBm~+3dBm Uncertainty: ±5%(-25dBm, CW)
3.Stable light source (optional)
Operating wavelength: the same as OTDR Output power: ≥-5dBm
Operating mode: CW, 270Hz, 1kHz and 2kHz

Technical specifications for each standard module of TL6000 OTDR1

Module number  

Operating wavelength

Laser wave length Dynamic range2 (dB) Event dead zone3

(m)

ATT

dead zone4 (m)

TL6000–1105 Single-mode 1625nm (built-in

filter)

 

 

Single- wavelength

36  

0.8

 

3

TL6000–1106 Single-mode 1650nm (built-in

filter)

36
TL6000–1201 Multi-mode 850nm 24 1 5
TL6000–1202 Multi-mode 1300nm 36
TL6000–2101 Single-mode 1310/1550nm  

 

 

 

Dual- wavelength

37 / 35  

 

 

 

0.5

 

 

 

 

3

TL6000–2102 Single-mode 1310/1550nm 42 / 40
TL6000–2103 Single-mode 1310/1550nm 45 / 42
TL6000–2105 Single-mode 1550/1625nm

(built-in filter)

36 / 36
TL6000–2107 Single-mode 1550 /1650nm

(built-in filter)

36 / 36
TL6000-2109 Single-mode 1310 /1550nm 46 / 46
TL6000–2108 Single-mode 1310/1550nm 30 / 28
TL6000–2201 Multi-mode 850nm/1300nm 26/34 0.7 5
TL6000–3101 Single-mode 1310/1490/1550nm  

 

 

 

Three- wavelength

37/35/35  

 

 

 

 

0.5

 

 

 

 

 

3

TL6000–3102 Single-mode

1310/1550/1625nm(built-in filter)

37/35/35
TL6000–3103 Single-mode

1310/1550/1625nm(built-in filter)

42/40/40
TL6000–3104 Single-mode 1310/1550 /1650

nm(built-in filter)

42/40/40
TL6000–3105 Single-mode

1310/1550/1650nm(built-in filter)

37/35/35
TL6000–3106 Single-mode

1310/1550/1625nm(built-in filter)

30/28/28
 

TL6000–4101

Single-mode 1310/1490/1550/1625nm(built-in

filter)

 

 

 

Four- wavelength

 

37/35/35/35

 

 

0.5

 

 

3

 

TL6000–4105

Single-mode 1310/1490/1550/1650nm(built-in

filter)

 

37/35/35/35

TL6000-4001 Single-mode 1310/1550nm, multi-mode 850/1300nm 37/35/26/34 0.7 5
TL6000-4002 Single-mode 1310/1550nm, multi-mode 850/1300nm Four- wavelength 30/28/24/28 0.7 5

Notes:
1. One must and only one can be chosen for the standard module.
2.An ambient temperature of 23℃±5℃, the maximum test PW, over 500 times averagely, and a SNR of 1.
3.A range of 1.6km or smaller, a PW of 3ns, a fiber end face reflection loss of 40dB or above, and a typical value.
4.A range of 1.6km or smaller, a PW of 5ns or smaller, a fiber end face reflection loss of 50dB or above, and a typical value.

Options and Accessories

Order Information

Main unit: TL6000 OTDR
Standard configuration:

S/N Description Remarks
 

1

 

Power line assembly

Power line and power adapter: an input voltage of 100~240V, 50~60Hz, an output voltage and an output current of 19V and

3.42A respectively at 2.0A

2 User manual
3 Product certificate

of conformity

4 CD Including simulation analysis software
5 Special portable

soft bag of OTDR

6 Special strap of

OTDR

Options:

` Description Function
TL6000-001 USB USB
TL6000-002 SD card SD card
TL6000-003 USB data cable USB data cable
TL6000-004 Spare battery pack 6417LB-1192
TL6000-005 LC, SC and ST adapters LC, SC and ST adaption
TL6000-006 Single-mode optical fiber

adaption jumper

FC/UPC adapted to FC/APC
TL6000-007 Single-mode optical fiber

adaption jumper

FC/UPC adapted to SC/UPC
TL6000-008 Single-mode optical fiber

adaption jumper

FC/UPC adapted to LC/UPC
TL6000-009 Special engineering plastic

case of OTDR

Special engineering plastic case

(including the strap)

Packing case:

Special soft bag

        

Special engineering plastic case(option)

Informationfor choosing:

Note: Due to the design improvement requirement, the contents mentioned above can be modified without notice.

Resources

TL6000 Large Dynamic Range OTDR-Transferline Microwave Technologies – – DOWNLOAD

Leave Us A Message

message

Reated Products